beautypg.com

Using the rangetop, 17 using the rangetop, Burner control knobs – Hestan 48 Inch Freestanding Dual Fuel Range Use and Care Manual User Manual

Page 19: Burner types & output, Re-ignition, Manual lighting / power failure

background image

© 2019 Hestan Commercial Corporation

17

EN

USING THE RANGETOP

BURNER CONTROL KNOBS

Each sealed burner has its own control knob. The symbol below each knob indicates which burner is

controlled by each knob. Push and turn LEFT (counter-clockwise) to HI to ignite the flame, then turn

to the desired flame setting.

BURNER TYPES & OUTPUT

This table below indicates

the type and output of

each sealed burner. Dual-

flow burners have an inner

and outer row of ports,

with a simmer function.

The single-flow burner

(some models) is similar to

a commercial burner and

features very high output,

and a low, but no simmer

function.

RE-IGNITION

Each sealed burner has its own electronic spark-ignition module with flame-sensing technology and

automatic re-ignition capability. If any burner should blow out, the igniter automatically re-lights the

burner.
Each burner should light in less than 4 seconds. Once lit, the sparking will stop. On very low simmer,

an occasional sparking may occur. This is usually due to a breeze in the room. If an igniter continues

to spark even with a flame present, there could be an electrical wiring issue, or some other problem.

See the TROUBLESHOOTING section of this manual for more information.

DO NOT touch the burner or the igniters while sparking is occurring. A shock hazard or burns could

occur.

MANUAL LIGHTING / POWER FAILURE

THE OVEN AND GRIDDLE CANNOT BE USED DURING A POWER FAILURE.
Each sealed burner can be manually lit in the event of a power failure. It is necessary to light each

burner individually.
If a power failure occurs WHILE you are using the sealed burners, turn all the knobs to the OFF

position - then light manually with a match or fireplace lighter.
Position the match or fireplace lighter at the port nearest the igniter, then turn the knob to HI until

the flame is lit. Wait until the flame has lit all the way around the burner before adjusting the knob

to LOW or SIMMER.
IF YOU SMELL GAS, turn all control knobs to OFF - check the precautions listed in the SAFETY

section of this manual.

DUAL-FLOW

(FRONT)

OUTPUT

(BTU/hr)

DUAL-FLOW

(REAR)

OUTPUT

(BTU/hr)

SINGLE

GRIDDLE

FLOW

OUTPUT

(BTU/hr)

HI

23000

HI

15500

MAX

30000

LOW

4200

LOW

4200

LOW

4200

15000

GRIDDLE

15000

SIMMER HI

1500

SIMMER HI

1500

SIMMER LOW

500

SIMMER LOW

500

DUAL-FLOW

(FRONT)

OUTPUT

(BTU/hr)

DUAL-FLOW

(REAR)

OUTPUT

(BTU/hr)

SINGLE

FLOW

OUTPUT

(BTU/hr)

HI

23000

HI

15500

MAX

22000

LOW

4200

LOW

4200

LOW

SIMMER HI

1500

SIMMER HI

1500

SIMMER LOW

600

SIMMER LOW

600

BURNER OUTPUT - PROPANE

4200

BURNER OUTPUT - NATURAL GAS