beautypg.com

Write, read check, Read, verify check, D-26 – Epson LT-286 User Manual

Page 151: The data on the highest physical cylinder

background image

Select option 1 from the menu to start this test. The program
displays the number of each cylinder it finds, counting down to 0.

The seek is performed by the read/write heads simultaneously, so

you see the cylinder numbers only once. If no errors occur, the
menu is redisplayed.

Write, Read Check

This check tests the ability of the hard disk drive to read and write

data. The test writes to and reads from each sector of the innermost
cylinder of the disk, using each head.

N o t e

This test destroys all data on the innermost cylinder of the hard
disk drive. This cylinder is reserved for diagnostics, however, and

is never used for storage by MS-DOS. Therefore, data created by

MS-DOS is not destroyed.

Select option 2 from the menu to start this test. You see this

message:

The data on the highest physical
cylinder

may

be destroyed by this check.

Enter Y to start this check.

Enter N to return to the menu.

Press Y and then

Enter

to continue the test.

You do not see a cylinder count during the test. If no errors occur,

the program returns to the menu.

If an error is reported, make a note of the code and message. Then
consult your dealer.

Read, Verify Check

This test reads and verifies data from all tracks of the disk, checking

each cylinder and using all heads.

D-26

Performing System Diagnostics