306
PARAMETER VALUE
DESCRIPTION
function
getstatus,
onetimeauto
"onetimeauto"
: Camera will automatically adjust the IR
zone one time only.
"getstatus"
: Information of optimized IR control status and
return value as below:
optimizedir_c<0~(n-1)>_irmode:
Indicate the IR current mode, available value is “auto” and
“manual” mode.
optimizedir_c<0~(n-1)>_irnum:
The number of IR that camera supports.
optimizedir_c<0~(n-1)>_irstrength:
Only available when irmode is set as manual. It’s a set of
integers, which indicate the strength of each IR LED (e.g.
23,45,100,100).
optimizedir_c<0~(n-1)>_irstatus:
Current IR status, normal / adjusting:
"normal":
the IR LED strength has been fixed.
"adjusting":
the IR LED strength is adjusting.
optimizedir_c<0~(n-1)>_supportmode:
“auto”
: automatically adjust the IR control.
“manual”
: manual adjustment.
Example:
http://myserver/cgi-bin/admin/optimizedir.cgi?function=getstatus
Response:
HTTP/1.0 200 OK\r\n
Cache-control: no-cache\r\n
Pragma: no-cache\r\n
\r\n
"optimizedir_c0_irmode='auto'"
"optimizedir_c0_irnum='5'"
"optimizedir_c0_irstrength='1,97,100,100,100'"
"optimizedir_c0_irstatus='normal'"
Syntax:
(for control API)
http://
?channel=
manual[&strength=
© 2022 VIVOTEK INC. All Right Reserved
307
PARAMETER
VALUE
DESCRIPTION
channel
0~"capability_nvideoin"-1 Channel of the video source.
operation
set,
settoall
"set"
: set the strength of each IR LED separately
"settoall"
: use fixed strength for all IR LED
irmode
auto,
manual
Irmode needs to be set as manual for adjusting IR
LED strength.
strength
1~100
If the operation is set as "set", the number of
strength values need to be the same as it of
irnum. However, it needs only one value for
strength when the operation is set as "settoall".
Example:
http://myserver/cgi-bin/admin/optimizedir.cgi?channel=0&operation=set&irmode=manual&
strength=50,70,50,50,50
Response:
HTTP/1.0 200 OK\r\n
Cache-control: no-cache\r\n
Pragma: no-cache\r\n
\r\n
"optimizedir_c0_irstrength='50,70,50,50,50'"
"optimizedir_c0_irmode='manual'"
Example:
http://myserver/cgi-bin/admin/optimizedir.cgi?channel=0&operation=settoall&irmode=manual&str
ength=100
Response:
HTTP/1.0 200 OK\r\n
Cache-control: no-cache\r\n
Pragma: no-cache\r\n
\r\n
"optimizedir_c0_irstrength='100,100,100,100,100'"
"optimizedir_c0_irmode='manual'"
Example: