VIVOTEK
382 - User's Manual
© 2022 VIVOTEK INC. All Right Reserved
252
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
stopbit
1,2
4/4
"1"
: One stop bit is transmitted to
indicate the end of a byte.
"2"
: Two stop bits are transmitted to
indicate the end of a byte.
If you want to transfer the stopbit for
150% of the normal time used to
transfer one bit, the
uart_i<0~(n-1)>_stopbit should be set
as 2 and the uart_i<0~(n-1)>_databit
set as 5 as well.
uartmode
rs485
4/7
RS485 mode.
7.44
UART Control (SC Series)
Group:
uart_i<0~(n-1)>
n is uart port count
(capability_nuart > 0 and capability_ibis = 1)
NAME
VALUE
SECURITY
(get/set)
DESCRIPTION
baudrate
1200,2400,4800,960
0,19200,38400
4/4
Set baud rate of COM port.
databit
5,6,7,8
4/4
Data bits in a character frame.
paritybit
none,
odd,
even
4/4
For error checking.
stopbit
1,2
4/4
"1"
: One stop bit is transmitted to
indicate the end of a byte.
"2"
: Two stop bits are transmitted to
indicate the end of a byte.
If you want to transfer the stopbit for
150% of the normal time used to
transfer one bit, the
uart_i<0~(n-1)>_stopbit should be set
as 2 and the uart_i<0~(n-1)>_databit
set as 5 as well.
7.45
Lens Configuration