If the ND filter will not move, you can move the filter to the CLEAR position manually using the
following procedure.

1.

Set the ON/STANDBY switch to STANDBY.

2.

Remove the round cap on the bottom side.

3.

Insert a screwdriver in the hole and turn it counterclockwise.
The ND filter moves to the CLEAR position by turning counterclockwise. Continue turning until
reaching the CLEAR position.
Use a screwdriver with ø2.4 mm diameter or smaller. The insertion depth of the screwdriver is about
3.2 cm (1 5/16 in.).

4.

Set the ND FILTER mode switch

(page 8)

to the PRESET position, and set the ND FILTER switch

(page 8)

to CLEAR.

Notes

• Do not use the procedure above during normal operation. Only use this procedure if the ND filter will not move. The

ND filter may become damaged if this procedure is used during normal operation.

• After the procedure above is used, consult a Sony service center to have the camcorder repaired.
• If an error message still appears after performing the procedure above, shooting is still possible.

ND filter dial