Configure the Adapter for Master/Slave Communication

FLEX I/O™ PROFIBUS Adapter

Page 54 of 152

ProSoft Technology, Inc.

August 23, 2007

User Parameter Example

User Parameter Message, Auto Configure Format

Name Value

Description

Octet 8:

00h

Reserved.

Octet 9:

00h

Auto Configure Format, Reset to Zero on Fault

Octet10 to 244

00h

Not used

5.2.3 Condensed

Format

The condensed format consists of the flags byte and the module key parameter
for each of the eight slots. This parameter dictates which I/O module must be
installed. If at any time the actual module ID does not match this module key, the
slot will be considered in fault and the following occurs:
ƒ

STATUS LED flashes red/off

ƒ

an error bit in the poll response data is set

ƒ

a diagnostic bit in the Ext_Diag_Data field returned in the Read DP-Slave

Diagnostic Information message response is set

All eight slots must be configured. The condensed format structure must be
repeated for each of the eight slots.

Data format for Condensed Format

Name Size

Description

Module Key

WORD

Module ID # that must be installed1

1 Only bits 0 to 12 are used. Bits 13 to 15 must be zero except when keying an empty slot where
0FFFFh is used.

The following table shows the identification numbers for current FLEX I/O
modules.

FLEX I/O Module Catalog Number

Module Identification Number (module key)

Four-word Modules

1794-IB16 0281h
1794-OB16 0191h
1794-IA8 0285h
1794IA8I 0280h
1794-OA8 0195h
1794-IB8S 0289h
1794-OW8 0199h
1794IA16 0209h
1794OA8I 019Ch
1794OA16 010Dh
1794IM8 0205h
1794OM8 0105h
1794IB8 0180h
1794IV16 0204h
1794OB8 0190h