Ext_User_Prm_Data_Ref(6) = 256;
EndModule
; Flex I/O module 1794-IE8, (default config= 9 words in, 0 word out)
Module = "1794-IE8 / Full format" 0x58, 0x00
Ext_Module_Prm_Data_Len = 5
Ext_User_Prm_Data_Const(0) = 0x19, 0x24, 0x10, 0x00, 0x00
;Config word 1
Ext_User_Prm_Data_Ref(3) = 11
EndModule
; Flex I/O module 1794-OE4, (default config= 1 word in, 4 words out)
Module = "1794-OE4 / Full format" 0x50, 0x63
Ext_Module_Prm_Data_Len = 15
Ext_User_Prm_Data_Const(0) = 0x11, 0x25, 0x24, 0x00, 0x00, 0x00, 0x00, 0x00, \
0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00
; Safe state word 1-4
Ext_User_Prm_Data_Ref(3) = 7
Ext_User_Prm_Data_Ref(5) = 8
Ext_User_Prm_Data_Ref(7) = 9
Ext_User_Prm_Data_Ref(9) = 10
;Config word 1
Ext_User_Prm_Data_Ref(12) = 12
Ext_User_Prm_Data_Ref(12) = 13
Ext_User_Prm_Data_Ref(12) = 14
Ext_User_Prm_Data_Ref(12) = 15
;Config word 2
Ext_User_Prm_Data_Ref(13) = 11
EndModule
; Flex I/O module 1794-IE4XOE2, (default config= 5 words in, 2 words out)
Module = "1794-IE4XOE2 / Full format" 0x54, 0x61
Ext_Module_Prm_Data_Len = 11
Ext_User_Prm_Data_Const(0) = 0x15, 0x26, 0x22, 0x00, 0x00, 0x00, 0x00, 0x00, \
0x00, 0x00, 0x00
;Safe state word 1-2
Ext_User_Prm_Data_Ref(3) = 7
Ext_User_Prm_Data_Ref(5) = 8
;Config word 1
Ext_User_Prm_Data_Ref(8) = 12
Ext_User_Prm_Data_Ref(8) = 13
;Config word 2
Ext_User_Prm_Data_Ref(9) = 11
EndModule
; Flex I/O module 1793-IE4(S), (default config= 9 words in, 0 word out)
Module = "1793-IE4(S) / Full format" 0x58, 0x00
Ext_Module_Prm_Data_Len = 5
Ext_User_Prm_Data_Const(0) = 0x19, 0x60, 0x10, 0x00, 0x00
;Config word 1
Ext_User_Prm_Data_Ref(3) = 52
Ext_User_Prm_Data_Ref(4) = 51
EndModule