ProSoft Technology MVI56E-MNET/MNETXT User Manual
Page 64
Configuring the MVI56E-MNET Module
MVI56E-MNET / MNETXT ♦ ControlLogix Platform
User Manual
Modbus TCP/IP Interface Module
Page 64 of 181
ProSoft Technology, Inc.
April 23, 2014
If the Test Connection procedure fails, you will see an error message. To correct
the error, follow these steps.
1 Click OK
to dismiss the error message.
2 In the Download
dialog box, click B
ROWSE
D
EVICE
(
S
) to open ProSoft
Discovery Service.
3 Select the module, and then click the right mouse button to open a shortcut
menu. On the shortcut menu, choose S
ELECT FOR
PCB.
4 Close ProSoft Discovery Service.
5 Click D
OWNLOAD
to transfer the configuration to the module.
2.4.1 Using CIPconnect to Connect to the Module
You can use CIPconnect
®
to connect a PC to the MVI56E-MNET module over
Ethernet using Rockwell Automation’s 1756-ENBT EtherNet/IP
®
module. This
allows you to configure the MVI56E-MNET module and network, upload and
download files, and view network and module diagnostics from a PC. RSLinx is
not required when you use CIPconnect. All you need are:
The IP addresses and slot numbers of any 1756-ENBT modules in the path
The ControlNet node numbers and slot numbers of any 1756-CNBx
ControlNet Bridge modules in the path
The slot number of the MVI56E-MNET in the destination ControlLogix chassis
(the last ENBT/CNBx and chassis in the path).
To use CIPconnect, follow these steps.