Status Data in the Read Block
The following table describes in more detail the status information contained in
the Read block.

Word Offset

Content

Description

202

Program Scan Count

This value is incremented each time a complete
program cycle occurs in the module.

203

Read Block Count

This field contains the total number of read blocks
transferred from the module to the processor.

204

Write Block Count

This field contains the total number of write blocks
transferred from the processor to the module.

205

Parse Block Count

This field contains the total number of blocks
successfully parsed that were received from the
processor.

206

Command Event Block
Count

This field contains the total number of command event
blocks received from the processor.

207

Command Block Count

This field contains the total number of command blocks
received from the processor.

208

Error Block Count

This field contains the total number of block errors
recognized by the module.

209

Product Code 1

This register displays the first word of the product code
in ASC format

210

Product Code 2

This register displays the second word of the product
code in ASC format

211

Version number

This register displays the version number in decimal
values. For example, if the version number is 1.51, it
will display as 151.

212

Reserved

Not used

213

Reserved

Not used

214

Reserved

Not used

215

Reserved

Not used

216

Reserved

Not used

217

Reserved

Not used

218

Reserved

Not used

219

Reserved

Not used

220

Reserved

Not used

221

Reserved

Not used

222

MNet Request Count

This counter increments each time an MNet (port 2000)
request is received.

223

MNet Response Count

This counter is incremented each time an MNet (port
2000) response message is sent.

224

MNet Errors Sent Count

This counter increments each time an MNet (port 2000)
sends an exception response to Client. Example: Client
sent illegal Modbus Data location address.

225

MNet Errors Received
Count

This counter increments each time an MNet (port 2000)
receives a bad command. Example: Client sent illegal
function command.

226

Configuration Error Word This word contains a bit map that indicates Client and

server configuration errors.

227

Reserved

Not used

228

Reserved

Not used