2 checking the event logs – PLANET NAS-7410 User Manual
Page 98
4-Bay SATA NAS RAID Server with iSCSI
NAS-7410
98
Thermal settings
User can also define the thermal scheme of the NAS server so that NAS server can give off
warning message or shutting down when the system or CPU temperature is over a predefined
threshold temperature.
Configuring thermal settings:
1. Go to Thermal Settings in Event→Configuration menu.
2. You can set the NAS server to give off warning message or shutdown base on the CPU or
System temperature. Check the Warning and Shutdown checkboxes and select the proper
temperature from the pull down menu.
3. Click Advance button to configure the way of notification for various events.
4. Click Apply to save the setting.
The system and CPU fan would start to work over 25 .
℃
11.2 Checking the event logs
You can view a summary of all the events occurred on your
NAS server: Web Reminder, System Log, Device Log & Security Log. The severity of each
event will be determined by NAS server and displayed in different colors:
Information = Green Warning = Yellow Error = Red
Viewing web reminder