©Retrotec Inc. 2012

Time averaging, seconds

4

4

4

4

4

4

4

Actual leakage area as measured,

8 in

2

12 in

2

16 in

2

20 in

2

24 in

2

28 in

2

32 in

2

Press [Set Pressure]

60Pa

60Pa

60Pa

60Pa

60Pa

60Pa

60Pa

Read peak pressure from gauge

92Pa

83Pa

71Pa

60Pa

60Pa

60Pa

60Pa

Read peak % speed from gauge

34%

33%

32%

37%

49%

61%

76%

Read final % speed from gauge

15%

18%

27%

37%

49%

61%

76%

If you believe you have a more severe problem with overshoot, fill out the table below and send it to
tech-support.

Device [1000, 2000, 3000]

Range, [C4, C2, C1]

Time averaging, seconds

Actual leakage area as measured,

Press [Set Pressure]

Read peak pressure from gauge

Read peak % speed from gauge

Read final % speed from gauge

Set the correct Device on your gauge because it will calculate different results depending on which
Device is selected.

9.10 Keep the Keep Rechargeable Batteries in top shape

The DM-2 is designed to recharge NiMH batteries in the gauge, eliminating the need to purchase a
stand-alone battery charger. The charging cycle is designed to fully discharge batteries before
recharging them. This can cause problems if the DM-2 is connected to a power plug for only brief
periods of time.

If the gauge exhibits any of the following conditions, it may be a problem with the rechargeable
batteries:

Short battery life

Will not turn on

Keys will not respond

Loss of power during test

The solution is to reset gauge and charge the batteries, or switch to non-
rechargeable batteries (remember to change the setting to tell the gauge
about the switch in battery type using

[Settings]

to set the “Battery Type”.

To charge the batteries:

1. Connect the AC power supply if rechargeable NiMH batteries are already installed.