determined which ones are the most often-used, cutting down on time required to prepare the gauge
for each test. Disabled Range Configurations can always be enabled if necessary.

Table 6: DM-2 compatible devices and associated Flow Range configurations

Calibrated Fan

Available Range Configurations

Retrotec 600/700

Open, 12, 8, 6, 2, 1

Retrotec 800/900

18F, 18R, 9, 5, 3, 1.4, 1.3, 1.2, 1.1, 0.1

Retrotec 1000 *

Open, A, B, C8, C6, C4, C2

Retrotec /2000/3000/3000SR

Open, A, B, C8, C6, C4, C3, C2, C1, L4, L2, L1

Retrotec DU100

Open, 2, 1

Retrotec DU200 *

Open, Mid, Low

Minneapolis DuctBlaster B

Open, Ring 1, Ring 2, Ring 3

Minneapolis Model 3/4

Open, A, B, C, D, E

Minneapolis Exhaust Fan

E1, E2, E3

Minneapolis True Flow

#14, #22

Infiltec E3

Open, 7 Holes, 4 Holes, 3 Holes, 2 Holes, 1 Hole

* White squares are the most commonly used Ranges and are set as defaults on your gauge. Grey
settings are turned off or inactive. Your gauge may be set up differently by a Vendor of yourself.

To enable/disable Flow Range configurations in Device [Setup]

1. Enter the “Device Setup” menu by pressing [Enter] on “Device Setup”.
2. Select the device on which Range Configurations need to be enabled/disabled and press

[Enter]

.

3. Press [

] or [

] arrows to turn the Range Configurations on ("Yes") or off ("No").

3.3 Mode Setup

The gauge is set to use a preset measurement unit for each of the available result display Modes.

Table 7: Default result Mode set-up

Mode

Settings

Pressure

Pa

Flow

CFM

@ 50 Pa

EfLA

Off

@ 4 Pa

EqLA

Off

@ 10 Pa

Air Changes

/h

@ 50 Pa

Flow per Area

cfm/100 sq ft

@ 25 Pa

EqLA per Area

Off

@ 50 Pa

EfLA per Area

Off

@ 50 Pa

Hole Flow

Off

n/a