Mode setup, 3 mode setup – Retrotec DM-2 User Manual
Page 28
Page 28 of 72
©Retrotec Inc. 2012
determined which ones are the most often-used, cutting down on time required to prepare the gauge
for each test. Disabled Range Configurations can always be enabled if necessary.
Table 6: DM-2 compatible devices and associated Flow Range configurations
Calibrated Fan
Available Range Configurations
Retrotec 600/700
Open, 12, 8, 6, 2, 1
Retrotec 800/900
18F, 18R, 9, 5, 3, 1.4, 1.3, 1.2, 1.1, 0.1
Retrotec 1000 *
Open, A, B, C8, C6, C4, C2
Retrotec /2000/3000/3000SR
Open, A, B, C8, C6, C4, C3, C2, C1, L4, L2, L1
Retrotec DU100
Open, 2, 1
Retrotec DU200 *
Open, Mid, Low
Minneapolis DuctBlaster B
Open, Ring 1, Ring 2, Ring 3
Minneapolis Model 3/4
Open, A, B, C, D, E
Minneapolis Exhaust Fan
E1, E2, E3
Minneapolis True Flow
#14, #22
Infiltec E3
Open, 7 Holes, 4 Holes, 3 Holes, 2 Holes, 1 Hole
* White squares are the most commonly used Ranges and are set as defaults on your gauge. Grey
settings are turned off or inactive. Your gauge may be set up differently by a Vendor of yourself.
To enable/disable Flow Range configurations in Device [Setup]
1. Enter the “Device Setup” menu by pressing [Enter] on “Device Setup”.
2. Select the device on which Range Configurations need to be enabled/disabled and press
[Enter]
.
3. Press [
] or [
] arrows to turn the Range Configurations on ("Yes") or off ("No").
3.3 Mode Setup
The gauge is set to use a preset measurement unit for each of the available result display Modes.
Table 7: Default result Mode set-up
Mode
Settings
Pressure
Pa
Flow
CFM
@ 50 Pa
EfLA
Off
@ 4 Pa
EqLA
Off
@ 10 Pa
Air Changes
/h
@ 50 Pa
Flow per Area
cfm/100 sq ft
@ 25 Pa
EqLA per Area
Off
@ 50 Pa
EfLA per Area
Off
@ 50 Pa
Hole Flow
Off
n/a