Retrotec DM-2 User Manual
Page 26

Page 26 of 72
©Retrotec Inc. 2012
Device Mfr
Device displayed
Description
*Retrotec DU200
Model 200 fan, Q32 DucTester
Retrotec 600/700
Obsolete fans
Retrotec 800/900
7
*Retrotec 1000
Model 1000 systems with 0.75 hp yellow wheel rim style fans
Retrotec 2000
Model Q46 and Q56 systems with 0.75 hp yellow foam core fan.
Same curves as 1000.
Retrotec 3000
Older Model Q4E, Q5E and QMG systems with 2 hp yellow foam
core Door Fan. Same curves as 1000.
Retrotec 3000SR
Model Q4E, Q5E and QMG systems with 2 hp yellow foam core
Door Fan – all fans are self-referencing (have green tube)
TEC
Mn Duct Blaster B
Duct testing fan
TEC
Mn Model 3 (120V)
0.75 hp black wheel rim style fan
TEC
Mn Model 3 (240V)
TEC
Mn Model 4 (240V)
TEC
Exhaust Fan Flow
Meter
Exhaust Fan Flow Meter – measures air flow through residential
exhaust fans between 10 and 124 CFM. This Device does not
currently work on many DM-2s since the minimum pressure is set
to 10 Pa and typical pressures inside the Exhaust fan box are
typically 1 to 8 Pa. The pressure in Pascals and table from the mfr
must be used to determine flow.
TEC
TrueFlow®
True Flow Grid – measures flow through a residential air handler
Infiltec
Infiltec E3
0.75 hp black wheel rim style fan
*White squares are the most commonly used Devices and are set as defaults on your gauge. Grey
settings are turned off or inactive. Your gauge may be set up differently by a Vendor of yourself.
Model 200 Fan
600 Fan
900 Fan
1000 Fan
2000 Fan
3000 Fan
Mn Duct Blaster B
Mn Model 3/4 Fan