If the test pressure (20 in this case) is close to the desired reference pressure (25 Pa in this case), then
the correction is small and the value of n does not play as large a role. However, if the test pressure is
much higher or lower than the reference pressure, the error can be greater.
The @ Pressure feature is very useful for ensuring that results taken when the pressure was not
adjusted perfectly are still accurate.
To continue the above example: The flow at 20 Pa is 100 CFM. Actual n is 0.7, but this is unknown.
Instead, 0.6 will be used.
The gauge would calculate:
πΉπππ€@25 ππ =
25
π
Γ πΆπΉπ
20
π
πΉπππ€@25 ππ =
25
0.6
Γ 100
20
0.6
πΉπππ€@25 ππ = 114 πΆπΉπ
However, if it was known that n was 0.7, the flow at 25 should have been:
πΉπππ€@25 ππ =
25
0.7
Γ 100
20
0.7
πΉπππ€@25 ππ = 117 πΆπΉπ
This value is less than 3% off from what it should be. If the test pressure was within 1 or 2 Pa of the
reference pressure of 25 Pa, the @ Pressure reading would be exact.
To change the n value
1. Press [Setup] to access the βSetupβ menu.
2. Press [
ο±
] or [
ο°
] to select "n" in the list. Press [Enter].
3. Input the new value between 0.5 and 1. Press [Enter].
3.1.7 Power Down Hour
The Power Down Hour helps to maximize battery power by enabling the DM-2 to automatically turn off
when it has been inactive for a set time period. The feature can be set to any value between 0 and 255
hours. Applying a 0 value will disable the Power Down feature, and the DM-2 will never automatically
shut down.
To change the Power Down Hour
1. Press [Setup] to access the Setup menu.
2. Press [
ο±
] or [
ο°
] to select "Power Down Hour" in the list. Press [Enter].