If the test pressure (20 in this case) is close to the desired reference pressure (25 Pa in this case), then
the correction is small and the value of n does not play as large a role. However, if the test pressure is
much higher or lower than the reference pressure, the error can be greater.

The @ Pressure feature is very useful for ensuring that results taken when the pressure was not
adjusted perfectly are still accurate.

To continue the above example: The flow at 20 Pa is 100 CFM. Actual n is 0.7, but this is unknown.
Instead, 0.6 will be used.

The gauge would calculate:

πΉπ‘™π‘œπ‘€@25 π‘ƒπ‘Ž =

25

𝑛

Γ— 𝐢𝐹𝑀

20

𝑛

πΉπ‘™π‘œπ‘€@25 π‘ƒπ‘Ž =

25

0.6

Γ— 100

20

0.6

πΉπ‘™π‘œπ‘€@25 π‘ƒπ‘Ž = 114 𝐢𝐹𝑀

However, if it was known that n was 0.7, the flow at 25 should have been:

πΉπ‘™π‘œπ‘€@25 π‘ƒπ‘Ž =

25

0.7

Γ— 100

20

0.7

πΉπ‘™π‘œπ‘€@25 π‘ƒπ‘Ž = 117 𝐢𝐹𝑀

This value is less than 3% off from what it should be. If the test pressure was within 1 or 2 Pa of the
reference pressure of 25 Pa, the @ Pressure reading would be exact.

To change the n value

1. Press [Setup] to access the β€œSetup” menu.
2. Press [



] or [



] to select "n" in the list. Press [Enter].

3. Input the new value between 0.5 and 1. Press [Enter].

3.1.7 Power Down Hour

The Power Down Hour helps to maximize battery power by enabling the DM-2 to automatically turn off
when it has been inactive for a set time period. The feature can be set to any value between 0 and 255
hours. Applying a 0 value will disable the Power Down feature, and the DM-2 will never automatically
shut down.

To change the Power Down Hour

1. Press [Setup] to access the Setup menu.
2. Press [



] or [



] to select "Power Down Hour" in the list. Press [Enter].