beautypg.com

Setup menu, 1 setup menu – Retrotec DM-2 User Manual

Page 19

background image

Page 19 of 72
©Retrotec Inc. 2012

3 Set the Gauge up with only the Devices and results you use

regularly

While the gauge can be run using the default settings, configuring the gauge for a specific fan system
and testing protocol can save time and reduce the chance of making mistakes. Some systems may be
ordered with the correct settings for a specific region and for the equipment being used. The Setup
Menu provides access to a number of settings, including the Device and Mode Setup screens.

3.1 Setup Menu

The Setup Menu contains access to two sub-menus and a list of other setup options:

Table 3: Settings available on the gauge [Setup]

Setting

Default

Description

Full Screen Timeout

15

Time in seconds until the display becomes large – set to 0 if you never
want to use the large screen display option

Restore Settings

Set the gauge back to factory default settings

Language

English

Choose the display language on the gauge

Battery Type

Rechargeable Tells the gauge whether or not to charge the batteries.

If you change to

non rechargeable batteries be sure to set this to “Not Rechargeable” to
avoid damage

Display Version

Selecting this item shows the Version of the firmware, the chipset and the
date of last calibration (press [Exit] to get back to the Setup menu)

n

0.65

Set to 0.65 for house testing, 0.60 for ducts and 0.50 for air handler flow
measurements. Extrapolation factor used by the @ Pressure function

Power Down Hour

1

Set how many hours of inactivity need occur before the gauge powers
itself down to save battery life

Surface Area Unit

sq ft

Units to use with the entered value for Area

Building Volume Unit

cu ft

Units to use with the entered value for Volume

European , Separator

no

Use “,” instead of “. “ as the decimal point

Sig Figs

3.5

Set how many decimal points are used, and how the results are rounded

Device Setup

Access the Device Setup sub-menu to enable or disable devices (fans) to
choose only the Devices you use and thus limit the list of Devices that the
[Device] key scrolls through

Mode Setup

Access the Mode Setup sub-menu to choose which Results are available to
display on “Channel B Result”, and to choose the units for the results being
displayed