RISCO Group ACIS User Manual
Page 85
User Manual for ACIS Version
Uncontrolled when printed
© RISCO Group
76
Table 12: Add a Section
Field Name
Procedure
Section Name
Enter the name of the Section that you want.
HW Communication
Interval
The interval time is for semi-permanent connection. Enter the time in seconds.
Proxy drops the connection to RSP in case it is idle in this interval and then
would immediately reconnect again. This interval is used for load balancing at
RSP server. Defaults to 10 minutes. Minimum is one minute and maximum is 10
minutes.
Default language
Select the default language for the section.
User Update Interval
RSP will send the application data to hardware after this time interval. Enter the
interval time minutes. It defaults to minimum one minute and maximum 60
minutes.
Installer Company Name
The installer company name appears by default.
Installer Update Interval
RSP will send the application data to hardware after this time interval. Enter the
interval time in seconds. Defaults to 1 minutes and maximum is 60 minutes.
Location
Enter the name of the main location to be created for the section. This is a
mandatory field
Is KeyFree Section
Select this check box to mark the current section as a KeyFree Section. This
section will be used to move data from Risco Group’s existing KeyFree system
to RSP system. This would be an identifier for identifying the section meant for
transferring data from KeyFree System.
Is Main Section
This check box is only visible when you are editing the main section. This is an
identifier for identifying the Main Section. For all the sub-sections, this check
box will not be visible.
R/W Card Validity
The “end of validity” of card content for read/write card. Enter the interval time
in minutes This is the maximum time available for the user to swipe the card on
a Read/Write Reader. Defaults to 1440 minutes.
After this time expires the
reader does not allow access to the card.
Default Time Zone
A drop-down field populated with a list of predefined time zones across the
world. Select the required time zone.
This is a Section level time zone. Devices can have their own time zones.
Adjust Daylight Saving
Select this check box to adjust day light saving as per the Time Zone selected (if
the country practices day light saving).
Logging
The errors at runtime are logged for reference. This is useful for RISCO during
the maintenance activity.
Select the Enabled check box to enable logging. If you enable logging, you can
log the errors either in Database or in Windows NT.
Select either the Database or Windows NT check box depending upon where
you want to enable logging.
LDAP Server
This is used for authentication of the user. Whenever a user logs on to ACUS,
the RSP sends request to LDAP server for authentication with Installers login
credentials. Refer to
9.1.1
LDAP Server Configuration
for details about the
LDAP.