It is connected to an REX sensor/switch.
The request to exit sensor/switch is connected to the IO board
Rebound Delay
It is the time taken by the output of the sensor to settle down and be
functional again. Longer the delay longer will be the response time of the
sensor.
Normally Opened
Select the check box to ensure that the normal status of the sensor is
open. If this is not selected then the normal status is closed.
3. Enter the following details in the fields:
Table 9: Relay Modes
Field
Describe
Continuous Impulse
Figure 28
In this mode the Relay is in the ON state for the
duration as specified by Pulse duration and in the
OFF state for the period as specified by Activation
delay.
The mode can be set only for Custom Relays,
Forced Door relay and ‘Door Open Too Long’ relay
Default – Door Lock, Turnstile, Standard
Continuous Toggle (1 sec. Pulse)
In this mode the Relay toggles in ON and OFF state
with a delay of one second between the two states.
The mode can be set only for Custom Relays,
Forced Door relay and ‘Door Open Too Long’ relay.