48

8-PROBLEMS/CAUSES/SOLUTIONS

The room fan does not stop.

Stove cooling in progress.

Wait for the structure to cool down.

Faulty temperature probe.

Replace the faulty component.

The room fan does not work.

The temperature has not reached the

minimum start-up threshold.

Wait for the structure to warm up.

The thermal protection has been triggered

due to the fan overheating.

Verify what could be obstructing fan

rotation.

Faulty fan.

Replace the faulty component.

The room fan is not adjusted.

The stove has reached the room

temperature set by knob B and

automatically modulates it to the

minimum.

Increase the set temperature.

Faulty control panel.

Replace the faulty component.

Stove power is not adjusted.

The stove has reached the set room

temperature and automatically modulates

it to the minimum.

Increase the set temperature.

Faulty control panel.

Replace the faulty component.

No light signal on the stove power

switch.

The power cable is not connected to the

socket.

Connect the cable to the socket.

The switch is not set to I.

Turn the stove on using switch I.

No power supply.

Check the system.

Blown fuse.

Replace the fuses.

The remote control does not work.

The remote control battery is flat.

Replace the batteries.

Faulty remote control.

Replace the remote control.