Problems/causes/solutions – MCZ Yari AIR User Manual
Page 50

48
8-PROBLEMS/CAUSES/SOLUTIONS
The room fan does not stop.
Stove cooling in progress.
Wait for the structure to cool down.
Faulty temperature probe.
Replace the faulty component.
The room fan does not work.
The temperature has not reached the
minimum start-up threshold.
Wait for the structure to warm up.
The thermal protection has been triggered
due to the fan overheating.
Verify what could be obstructing fan
rotation.
Faulty fan.
Replace the faulty component.
The room fan is not adjusted.
The stove has reached the room
temperature set by knob B and
automatically modulates it to the
minimum.
Increase the set temperature.
Faulty control panel.
Replace the faulty component.
Stove power is not adjusted.
The stove has reached the set room
temperature and automatically modulates
it to the minimum.
Increase the set temperature.
Faulty control panel.
Replace the faulty component.
No light signal on the stove power
switch.
The power cable is not connected to the
socket.
Connect the cable to the socket.
The switch is not set to I.
Turn the stove on using switch I.
No power supply.
Check the system.
Blown fuse.
Replace the fuses.
The remote control does not work.
The remote control battery is flat.
Replace the batteries.
Faulty remote control.
Replace the remote control.