2-INSTALLATION INSTRUCTIONS

CONNECTIONS

CONNECTION TO THE CHIMNEY

CONNECTION TO AN

EXTERNAL DUCT WITH AN INSULATED

OR DOUBLE-WALL PIPE

CONNECTION TO THE CHIMNEY

The chimney's internal dimensions must

not exceed 20x20 cm or 20 cm diameter;

in the event of bigger sizes or bad chimney

conditions (e.g. cracks, poor insulation,

etc.), it is advisable to fit a stainless steel

pipe of suitable diameter throughout the

length of the chimney right to the top.

The minimum internal dimensions of the

external duct must be 10x10 cm or 10 cm

in diameter and must not exceed 20x20 cm

or 20 cm in diameter.

Only stainless steel insulated (double-wall)

pipes must be used, which are smooth on

the inside and fixed to the wall. Flexible

stainless steel pipes must not be used.

The connection between the product and

the chimney or the smoke duct must not

have an inclination that is less than 3% in

the horizontal sections, which must have

a maximum overall length of 2/3 m. The

vertical section between one T-fitting and

another (angle) must not be less than 1.5

m.

1) WINDPROOF CHIMNEYPOT 

2) CHIMNEY 

3) INSPECTION HOLE

•  Use adequate instruments to verify that there is a minimum draught of 5 Pa.

•  Set-up an inspection hole at the bottom of the chimney to perform periodic checks and cleaning, which must

be done annually.

•  The connection to the chimney must be sealed and the fittings and pipes recommended by us must be used (CE

marked in accordance with EN1856-2 with the minimum requisites: T200 and P1).

•  You must ensure that a windproof chimneypot is installed in accordance with the regulations in force.

•  This type of connection guarantees smoke expulsion even in the event of a temporary power cut.

Technical Dept. - All rights reserved - Reproduction is prohibited