MCZ Yari AIR User Manual
Page 48

46
8-PROBLEMS/CAUSES/SOLUTIONS
ANOMALY
POSSIBLE CAUSES
SOLUTIONS
Safety alarm.
Excessive pellet load.
Wait for the stove to cool down, re-ignite
it and reduce pellet loading by following
the instructions provided in the dedicated
paragraph herein.
Room fan power too low.
Wait for the stove to cool down, re-ignite it
and increase the fan power using knob A.
The door is not closed properly or the
gaskets are worn.
Close the door or replace the gaskets with
original ones.
The combustion chamber is dirty.
Clean the combustion chamber, following
the instructions in the manual.
Clogged outlet.
Clean the smoke duct.
Faulty or malfunctioning pressure switch.
Replace the pressure switch.
The structure overheats due to reduced
heat dissipation.
Verify the correct position of the stove.
Increase the smoke fan speed in accord-
ance with the technical manual.
Faulty room fan.
Replace the room fan.
The stove indicates that the smoke
fan is operating anomalously.
Fan rotation is obstructed.
Verify what the obstruction is.
Faulty smoke fan.
Replace the faulty component.