8-PROBLEMS/CAUSES/SOLUTIONS

ANOMALY

POSSIBLE CAUSES

SOLUTIONS

Safety alarm.

Excessive pellet load.

Wait for the stove to cool down, re-ignite

it and reduce pellet loading by following

the instructions provided in the dedicated

paragraph herein.

Room fan power too low.

Wait for the stove to cool down, re-ignite it

and increase the fan power using knob A.

The door is not closed properly or the

gaskets are worn.

Close the door or replace the gaskets with

original ones.

The combustion chamber is dirty.

Clean the combustion chamber, following

the instructions in the manual.

Clogged outlet.

Clean the smoke duct.

Faulty or malfunctioning pressure switch.

Replace the pressure switch.

The structure overheats due to reduced

heat dissipation.

Verify the correct position of the stove.

Increase the smoke fan speed in accord-

ance with the technical manual.

Faulty room fan.

Replace the room fan.

The stove indicates that the smoke

fan is operating anomalously.

Fan rotation is obstructed.

Verify what the obstruction is.

Faulty smoke fan.

Replace the faulty component.