8-PROBLEMS/CAUSES/SOLUTIONS

The stove reports that the smoke

temperature is too high or the smoke

probe is faulty.

Excessive pellet load.

Reduce the pellet load by following the

instruction provided herein.

Unsuitable pellets.

Empty the hopper from the unsuitable

pellets and replace them with those

recommended by the manufacturer.

Room fan power too low.

Increase fan speed.

The structure overheats due to reduced

heat dissipation.

Verify the correct position of the stove.

Faulty room fan.

Replace the faulty component.

Faulty smoke probe.

Replace the faulty component.

Clogged smoke outlet.

Clean the smoke exhaust.

Pellets accumulate in the brazier.

Excessive pellet load.

Decrease the pellet load.

Insufficient combustion air.

Make sure the combustion air inlet in the

rear part of the stove is not clogged or

obstructed.

Damp or unsuitable pellets.

Empty the hopper from the unsuitable

pellets and replace them with those

recommended by the manufacturer.

The door is open.

Make sure the door is closed.

Clogged smoke outlet.

Clean the smoke exhaust.

Worn gaskets.

Increase the smoke fan speed in accord-

ance with the instructions provided in the

technical manual.

Replace the gaskets.

The flame is weak or goes off.

The pellet hopper is running low.

Fill the hopper.

Low pellet load.

Increase the pellet load by following the

instructions.

Unsuitable pellets.

Empty the hopper from the unsuitable

pellets and replace them with those

recommended by the manufacturer.