Description

'q' read

index

0C 00

01

Energize C2: Set Cal Valves to RUN or LEAK Position
(default) — choice made by ii=12.
Energize C1: Set Cal Valves to CAL/RE-ZERO or
PURGE Position
— choice made by ii=12.

0B

see

chart

below

0D-0E

--

Reserved for factory use

0F 00

01

Disable periodic Thermal Coefficient Update task.
Enable periodic Thermal Coefficient Update task
(default).

10 01-FF

(1-255)

Set Number of A/D Samples to Average. (default = 8). 05

11

--

Reserved for factory use

12 00

01

Energize C4: Set Cal Valves to RUN or CAL/RE-ZERO
Position
(default) — choice made by ii=0C.
Energize C3: Set Cal Valves to PURGE or LEAK
Position
— choice made by ii=0C.

0B

see

chart

below

13 00

01

Use Static IP Address Resolution (default)
Use Dynamic IP Address Resolution

06

14 00

01

02

Disable TCP/IP Back-Off Delay (default).
Enable TCP/IP Back-Off Delay as low-order byte of
Ethernet Adrs.(converted to decimal value * 20 µSec.).
Enable TCP/IP Back-Off Delay specified per eeee as
decimal value (* 20 µSec.)

07

15

--

Reserved for factory use

16 00

01

Disable TCP/IP Data Field Size Prefix (default).
Enable TCP/IP Data Field Size Prefix (2-byte big-endian
binary value with total size of response data in bytes).

08

17 00

Set

TCP Connect Port per eeee as decimal value

(default=9000).

09

18 00

01

Disable Auto UDP Broadcast@Reset (default).
Enable Auto UDP Broadcast@Reset.

0A

19 00

01

Set Minimum Temperature Alarm Set Point (in

0

C)

per eeee as decimal value (default = 0

0

C).

Set Maximum Temperature Alarm Set Point ( in

0

C)

per eeee as decimal value (default = 60

0

C).

0D

0E

1A 00

Set

External DH Scan Interval per eeee as decimal value

(seconds), 1 <= eeee <= 3600 (1 hour) (default = 60).

10