beautypg.com

Pressure Systems 98RK-1 User Manual

Page 72

background image

Pressure Systems, Inc. 98RK-1 & 9816 User’s Manual©

Page 70

www.PressureSystems.com

bbbb (hex)

data selected for inclusion in each stream packet

0001

Enable Valve Position Status (see next table)

0002

Enable DH Temperature Status (see bit map below)

0010

Enable Pressure EU Data (default if never executed)

0020

Enable Pressure A/D Counts*

0040

Enable Pressure Voltages*

0080

Enable DH Temperature EU Data (degrees C)*

0100

Enable DH Temperature A/D Counts*

0200

Enable DH Temperature Voltages*

Any Valve Position Status datum is delivered as a two-byte binary integer (16-bit, big endian)
with the following possible values (shown in hex below). If selected, this datum will follow the
stream header in each packet:

status (hex)

Valve Position Status

0000

Valves in RUN position

0001

Valves in CAL position

0010

Valves in LEAK/CHARGE position

0011

Valves in PURGE position


Any DH Temperature Status datum is delivered as a two-byte binary bit map (16-bit, big
endian) with each bit representing the status of DH #16 through DH #1 respectively. A bit value
of 0 (zero) indicates the DH is operating within its specified limits. A value of 1 (one) indicates
the DH is outside its specified limits.

Bit

# 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

Chan #

16

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1

Binary 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1

Hex

8 0 0 1


The above example indicates that Channels 1 and 16 are operating outside the specified
temperature limits. This binary datum, when selected, follows the previous Valve Position
status datum (or the stream packet header).