beautypg.com

2 detailed command description reference – Pressure Systems 98RK-1 User Manual

Page 43

background image

Pressure Systems, Inc. 98RK-1 & 9816 User’s Manual©

Page 41

www.PressureSystems.com

3.2

Detailed Command Description Reference

All commands applicable to the Model 9816 NetScanner

System models are described on

the following pages and summarized in the following table.

Table 3.1

Model 9816 NetScanner

System Commands

type

command id

function

A

Power-up Clear

B

Reset

C

Configure/Control Multi-Point Calibration (4 sub-
commands)

V

Read Transducer Voltages

Z

Calculate and Set Gains (Span Cal)

a

Read Transducer Raw A/D Counts

b

Read High Speed Data

c

Configure/Control Autonomous Host Streams (6 sub-
commands)

h

Calculate and Set Offsets (Re-zero Cal)

m

Read Temperature A/D Counts

n

Read Temperature Voltage

q

Read Module Status

r

Read High Precision Data

t

Read Transducer Temperature

u

Read Internal Coefficients

v

Download Internal Coefficients

TCP/IP

Commands

w

Set/Do Operating Options/Functions

psi9000

Query Network

psireboot

Reboot Specified Module

UDP/IP

Commands

psirarp

Change Specified Module’s IP Address Resolution
Method (then Reboot)


Refer to the particular user’s manuals for other (externally connected) 9016/9116, 9021/9022,
and 903x models for their specific commands.