2 detailed command description reference – Pressure Systems 98RK-1 User Manual
Page 43

Pressure Systems, Inc. 98RK-1 & 9816 User’s Manual©
Page 41
www.PressureSystems.com
3.2
Detailed Command Description Reference
All commands applicable to the Model 9816 NetScanner
™
System models are described on
the following pages and summarized in the following table.
Table 3.1
Model 9816 NetScanner
™
System Commands
type
command id
function
A
Power-up Clear
B
Reset
C
Configure/Control Multi-Point Calibration (4 sub-
commands)
V
Read Transducer Voltages
Z
Calculate and Set Gains (Span Cal)
a
Read Transducer Raw A/D Counts
b
Read High Speed Data
c
Configure/Control Autonomous Host Streams (6 sub-
commands)
h
Calculate and Set Offsets (Re-zero Cal)
m
Read Temperature A/D Counts
n
Read Temperature Voltage
q
Read Module Status
r
Read High Precision Data
t
Read Transducer Temperature
u
Read Internal Coefficients
v
Download Internal Coefficients
TCP/IP
Commands
w
Set/Do Operating Options/Functions
psi9000
Query Network
psireboot
Reboot Specified Module
UDP/IP
Commands
psirarp
Change Specified Module’s IP Address Resolution
Method (then Reboot)
Refer to the particular user’s manuals for other (externally connected) 9016/9116, 9021/9022,
and 903x models for their specific commands.