beautypg.com

8 storing measured values - data logger – Epson USN 52L User Manual

Page 80

background image

Krautkramer USN 52R/USN 52L

Issue 05, 02/00

5-35

5.8

Storing measured values -
Data Logger

The Data Logger helps you to store and manage your
measurement results. These are saved even when the
batteries are removed. The stored measured values can
be:

• displayed

• deliberately deleted

• transferred to a peripheral

• output via a PC or printer

A number of measurements are compiled into one
“FILE”. To file measured values in the Data Logger you
must

• determine the required number of FILES

• select a FILE

Determining the number of FILES

You determine the total number of FILES (max. 99) –
the instrument automatically determines the number of
measurement locations according to the following for-
mula:

Number of measurement locations = 2500 : Number
of FILES

The first measured value of each FILE is automatically
allocated the number 1. However, you can also select
another measurement location. All the following mea-
sured values are consecutively filed until all measure-
ment locations are full or until you select another FILE
or measurement location.

H Note:

You can only determine the number of FILES when the
Data Logger is empty.

Storing measured values - Data Logger

Operation

Krautkramer USN 52R/USN 52L

Issue 05, 02/00

5-35

5.8

Storing measured values -
Data Logger

The Data Logger helps you to store and manage your
measurement results. These are saved even when the
batteries are removed. The stored measured values can
be:

• displayed

• deliberately deleted

• transferred to a peripheral

• output via a PC or printer

A number of measurements are compiled into one
“FILE”. To file measured values in the Data Logger you
must

• determine the required number of FILES

• select a FILE

Determining the number of FILES

You determine the total number of FILES (max. 99) –
the instrument automatically determines the number of
measurement locations according to the following for-
mula:

Number of measurement locations = 2500 : Number
of FILES

The first measured value of each FILE is automatically
allocated the number 1. However, you can also select
another measurement location. All the following mea-
sured values are consecutively filed until all measure-
ment locations are full or until you select another FILE
or measurement location.

H Note:

You can only determine the number of FILES when the
Data Logger is empty.

Storing measured values - Data Logger

Operation

This manual is related to the following products: