beautypg.com

Epson USN 52L User Manual

Page 199

background image

DGS-24

Issue 02, 03/99

Krautkramer USN 52R/USN 52L Option DGS

H Note:

If the reference echo symbol does not appear, no refer-
ence echo was recorded. Possible reasons are:

• The reference echo is outside of the monitor gate.

• The amplitude of the refernce echo is either too low

or too high.

• The reference cho comes from a side drilled hole,

and the conditions to use it are not met (ref. to
chapter 3.2).

Correct the settings correspondingly and record the
reference echo again.

– Enter the required recording level in the ERS

function: N or O

– Switch the DGS mode on in the DGS function:

N or O

H Note:

The reference echo must have the highest amplitude
within the gate, as shown in the figure below:

Operating the DGS

Carrying out a DGS evaluation

– Record the reference echo: B

The status line shows the reference echo symbol:

DGS-24

Issue 02, 03/99

Krautkramer USN 52R/USN 52L Option DGS

H Note:

If the reference echo symbol does not appear, no refer-
ence echo was recorded. Possible reasons are:

• The reference echo is outside of the monitor gate.

• The amplitude of the refernce echo is either too low

or too high.

• The reference cho comes from a side drilled hole,

and the conditions to use it are not met (ref. to
chapter 3.2).

Correct the settings correspondingly and record the
reference echo again.

– Enter the required recording level in the ERS

function: N or O

– Switch the DGS mode on in the DGS function:

N or O

H Note:

The reference echo must have the highest amplitude
within the gate, as shown in the figure below:

Operating the DGS

Carrying out a DGS evaluation

– Record the reference echo: B

The status line shows the reference echo symbol:

This manual is related to the following products: