Installation

Main Panel

(Utility Power/Generator Input)

ME2000-15B/-20B

Inverters

AC Wiring Compartment

(AC input and output wiring)

SINGLE IN / DUAL OUT wiring

Direct from inverter

(Inverter Loads)

120

VAC

120

VAC

ON

OFF

ON

OF

F

ON

OF

F

ON

OF

F

ON

OFF

ON

OF

F

ON

OF

F

ON

OF
F

ON

OF
F

ON

OF
F

ON

OF
F

ON

OF
F

ON

OF
F

30

Maximum 30-amp breaker

(single pole) required to

inverter AC input.

In mobile installations: neutral is typically not

connected to ground in the main panel.

AC HOT IN

BLACK

WHITE

GREEN

BLUE

ORANGE

AC NEUT IN

AC GROUND

AC HOT 1 OUT

AC NEUT OUT

AC HOT 2 OUT

AC GROUND (x2)

Has optional 15-amp or 20-

amp branch-rated circuit

breakers (on side of unit).

WHITE w/ BLACK

AC NEUT OUT

WHITE w/ BLACK

Figure 2-15, AC Wiring for ME2000-15B/-20B Models