Yaskawa DriveWizard AC Drive User Manual
Page 141

P5
Par.
P5 Parameter Name
Conversion
E7/P7
Par.
E7/P7 Parameter
Name
n033
Motor OL Select
If n033 > 1, then L1-01 = 1
L1-01
Mtr OL Protect Select
n034
OH1 Stop Method
None
L8-03
OH Pre-Alarm Op Sel.
n035
Terminal S2 Select
If n035 >1, then table 4, else
H1-03 = 0Fh
H1-01
Terminal S3 Select
n036
Terminal S3 Select
Table 4
H1-02
Terminal S4 Select
n037
Terminal S4 Select
Table 4
H1-03
Terminal S5 Select
n038
Terminal S5 Select
Table 4
H1-04
Terminal S5 Select
n039
Terminal S6 Select
Table 4
H1-05
Terminal S5 Select
n040
Terminal MA Select
Table 5
H2-01
Terminal M1-M2 Sel.
n041
Terminal M1 Select
Table 5
H2-02
Terminal M3-M4 Sel.
n042
Master Analog Input
Sel.
NOT CONVERTED
NA
NA
n043
Terminal FI Select
If n043 =1, then H3-08 =2,
else H3-08 = 0
H3-08
Terminal A2 Signal
Level Select
n044
Freq Ref Retention
D
NOT CONVERTE
NA
NA
n045
Ref Loss Detect
oss Det Sel
None
L4-05
Freq Ref L
n046
Freq Ref Gain
n046*10 = H3-02
H3-02
Terminal A1 Gain
n047
Freq Ref Bias
n047*10 = H3-03
H3-03
Terminal A1 Bias
n048
Terminal AM Sel
Table 6
H4-01
Terminal FM Select
n049
Terminal AM Gain
n049*10 = H4-02
H4-02
Terminal FM Gain
n050
Carrier Freq select
NOT CONVERTED
NA
NA
n051
Pwr Loss Ride Thru sel
None
L2-01
Pwr Loss Det Select
n052
Spd Srch Current
None
b3-02
Spd srch Deact Current
n053
Min Baseblock Time
If n053 > 5.0 then L2-03 =
5.0, else n053 = L2-03
L2-03
Pwr Loss Min Base
Block Time
n054
Spd Search V/F
NOT CONVERTED
NA
NA
n055
Ride Thru Time None
L2-02
Pwr Loss Ride-Thru
Pwr Loss
Time
n056
Number of Restarts
None
L5-01
f Restart attempts
No.o
n057
Restart Select
If n057 = 1 then L5-02 = 0,
else L5-02 = 1
L5-02
Auto Restart Operation
Select
n058
Jump Freq 1
If n058 > 200.0, then d3-01
= 200.0, else n058 = d3-01
d3-01
Jump Frequency 1
n059
Jump Freq 2
If n059 > 200.0, then d3-02
= 200.0, else n059 = d3-02
d3-02
Jump Frequency 2
n060
Jump Bandwidth
If n060 > 20.0, then d3-04 =
20.0, else n064 = d3-04
d3-04
Jump Frequency Width
n061
Elapsed Timer Select
None
o2-08
Cum. Op Time Select
n062
Elapsed Time 1
NOT CONVERTED
NA
NA
n063
Elapsed Time 2
NOT CONVERTED
NA
NA
n064
DC inj Current
None
b2-02
nj Brkg Current
DC I
n065
DC inj Time @ Stop
n065*10 = b2-04
b2-04
DC INJ Time @Stop
n066
DC inj Time @ Start
n066*10 = b2-03
b2-03
DC INJ Time @ Start
n067
Torq Comp Gain
NOT CONVERTED
NA
NA
n068
Mtr Line to Line Res.
NOT CONVERTED
NA
NA
n069
Mtr Iron Loss
NOT CONVERTED
NA
NA
n070
Stall Prev Decel
None
L3-04
Stall Prevent Sel. During
l
Dece
n071
Stall Prev. Accel Lvl
NOT CONVERTED
NA
NA
n072
NA
Stall Prev Run Lvl
NOT CONVERTED
NA
141