Yaskawa YASNAC PC NC Programming Manual User Manual
Page 215

4 - 78
YASNAC PCNC Programming Manual
Chapter 4: Enhanced Level Commands
(a) Setting the boundary and area
The parameter numbers used for area designation are indicated in Table 4.2.3.1
Table 4.2.3.1
Parameter Numbers Used for Area Designation.
(b) Designation of check axes
The axes for which stored stroke limit B, C (No. 2 to No. 5 entry prohibited areas) is
checked is designated by using parameters (maximum of three axes).
Table 4.2.3.2
Stored Stroke Limit Check Axis Numbers for No. 2 to No. 5 Entry Pro-
hibit Areas
Note: Setting: I = X-axis, 2 = Y-axis, 3 = Z-axis
Boundary
Check Axis No.
No. 1
No. 2
No. 3
No. 2 prohibited area (+): A2 point
pm0831
pm0832
pm0833
No. 2 prohibited area (–): B2 point
pm0834
pm0835
pm0836
No. 3 prohibited area (+): A3 point
pm0837
pm0838
pm0839
No. 3 prohibited area (–): B3 point
pm0840
pm0841
pm0842
No. 4 prohibited area (+): A4 point
pm0843
pm0844
pm0845
No.4 prohibited area (–):
B4
point pm0846 pm0847 pm0848
No. 5 prohibited area (+): A5 point
pm0849
pm0850
pm0851
No. 5 prohibited area (–): B5 point
pm0852
pm0853
pm0854
Boundary
Check Axis No.
No. 1
No. 2
No. 3
No. 2 entry prohibited area
pm6111
pm6112
pm6113
No. 3 entry prohibited area
pm6114
pm6115
pm6116
No. 4 entry prohibited area
pm6117
pm6118
pm6119
No. 5 entry prohibited area
pm6120
pm6121
pm6122