10 Appendix 2 Parameter Cross Reference
54
YASKAWA PL.A1000.02 F7 to A1000 - Product Transition Guide
Display Setting/
Selection
Drive Mode Unit
Monitor Selection
o1-01
6
*
o1-01
106
*
*See the comments given for parameter F4-01.
User Monitor
Selection After
Power Up
o1-02
1
o1-02
1
o1-02
o1-02
1: Frequency reference
1: Frequency reference
2: Output frequency
3: Output frequency
3: Output current
4: Output current
4: User-selected Monitor
(set by o1-01)
5: User-selected Monitor (set by o1-01)
—
2: Direction
Digital Operator
Display Selection
o1-03
0
o1-03
*
o1-03
o1-03
0: Hz units
0: 0.01 Hz units
1: % units
(100 % = E1-04)
1: 0.01 % units
2 to 39: RPM
2: r/min units
40 to 39999: User display
3: User-set units
o1-10
o1-11
1 to 60000
0 to 3
o1-10: Determines how the units for the frequency reference.
o1-11: Sets the decimal point for the frequency reference display
*Determined by parameter A1-02
Ex. : For a max output frequency of 200.0, set the following:
Setting value :
o1-03=12000
Setting value: o1-03=3
: o1-10=2000
: o1-11=1
1 2 0 0 0
│ └ Max value, excluding decimal point → o1-10= “2000”
└── digits displayed to the right of the decimal → o1-11= 1
Setting Unit for
Frequency
Parameters Related
to V/f
Characteristics
o1-04
0
o1-04
*
o1-04
o1-04
0: Hz units
0: Hz units
1: r/min units
1: r/min units
*Determined by A1-02
LCD Brightness
o1-05
3
—
—
This parameter is not available in A1000.
Parameter Name
F7
A1000
Setting
Parameter
Default
Parameter
Default
F7
A1000