10 appendix 2 parameter cross reference – Yaskawa F7 to A1000 User Manual
Page 47

10 Appendix 2 Parameter Cross Reference
YASKAWA PL.A1000.02 F7 to A1000 - Product Transition Guide
47
Analog Input
Terminal A1
Signal Level
Selection
H3-01
0
H3-01
0
Terminal A1 in A1000 is multi-functional.
H3-01
H3-01
0: 0 to +10 V
0: 0 to +10 V (uses lower limit)
1: -10 to 10 V
1: -10 to 10 V (no lower limit)
Terminal A1
Function Selection
─
─
H3-02
0
For A1000, set H3-02 to 0.
Terminal A1 Gain
Setting
H3-02
100.0%
H3-03
100.0 %
—
F2-02
100.0 %
Set this parameter when using an analog option card to determine the gain added to
the analog reference.
Terminal A1 Bias
Setting
H3-03
0.0%
H3-04
0.0 %
F2-03
0.0 %
Set this parameter when using an analog option card to determine the gain added to
the analog reference.
Terminal A3
Signal Level
Selection
H3-04
0
H3-05
0
H3-04
H3-05
0: 0 to +10 V
0: 0 to +10 V (uses lower limit)
1: -10 to 10 V
1: -10 to 10 V (no lower limit)
Terminal A3
Function Selection
H3-05
2
H3-06
2
H3-05, H3-09
H3-06, H3-10
0: Terminal A1 bias
0: Frequency bias
1: Frequency reference
gain
1: Frequency gain
2: Auxiliary freq ref 1
2: Auxiliary freq ref 1
3: Auxiliary freq ref 2
3: Auxiliary frequency reference 2
4: Output voltage bias
4: Output voltage bias
5: Accel/decel time
coefficient
5: Accel/decel time gain
6: DC Injection Braking
current
6: DC Injection Braking current
7: Torque detection level
7: Torque detection level
8: Stall Prevention level
during run
8: Stall Prevention level during run
9: Frequency Ref. lower
limit
9: Output freq lower limit level
A: Jump frequency 4
—
B: PID feedback
B: PID feedback
C: PID setpoint
C: PID setpoint
D: Frequency Reference
bias 2
D: Frequency bias
E: Motor temperature
E: Motor temperature
F: Through- mode
F: Through- mode
Parameter Name
F7
A1000
Setting
Parameter
Default
Parameter
Default
F7
A1000