9 Appendix 1 Ratings
22
YASKAWA PL.A1000.02 F7 to A1000 - Product Transition Guide
Table 12 480 V Normal Duty Ratings
650
780
0930
810
2 (2)
150
—
—
—
—
900
1080
1200
1090
2 (2)
150
<1> Carrier setting in parenthesis indicates maximum without derating (applies to HD rating only).
<2> Heavy Duty overload current rating for model no. 42200 and 43000 is 150% of rated output current for 45 seconds.
480 V Normal Duty
NEC HP 460 V
NEC Amps
A1000 (C6-01 = 1)
F7 (C6-01 = 2)
A1000
Model
CIMR-AU4A
Output Amps
Normal Duty
Fc kHz
Normal Duty
Overload %
Normal Duty
F7
Model
CIMR-F7U
Output Amps
Normal Duty
Fc kHz
Normal Duty
Overload %
Normal Duty
0.5
1.1
0002
2.1
2 (SPWM)
120
40P41
1.8
15
120
0.75
1.6
40P41
1
2.1
0004
4.1
2 (SPWM)
120
40P71
2.1
15
120
1.5
3
41P51
3.7
15
120
2
3.4
3
4.8
0005
0007
5.4
6.9
2 (SPWM)
120
42P21
5.3
15
120
5.0
7.6
0009
8.8
2 (SPWM)
120
43P71
7.6
15
120
44P01
8.7
15
120
7.5
11
0011
11.1
2 (SPWM)
120
45P51
12.5
15
120
10
14
0018
17.5
2 (SPWM)
120
47P51
17
15
120
15
21
0023
23
2 (SPWM)
120
40111
27
8
107
20
27
0031
31
2 (SPWM)
120
25
34
0038
38
2 (SPWM)
120
40151
34
10
109
30
40
0044
44
2 (SPWM)
120
40181
40221
40
50.4
10
117
107
40
52
0058
58
2 (SPWM)
120
40301
67.2
8
107
50
65
0072
72
2 (SPWM)
120
60
77
0088
88
2 (SPWM)
120
40371
77
8
117
75
96
0103
103
2 (SPWM)
120
40451
96
8
114
100
124
0139
139
2 (SPWM)
120
40551
125
5
108
125
156
0165
165
2 (SPWM)
120
40750
156
5
115
150
180
0208
208
2 (SPWM)
120
40900
180
8
120
200
240
0250
250
2 (SPWM)
120
41100
240
5
108
41320
260
5
120
250
302
0296
296
2 (SPWM)
120
41600
304
5
120
300
361
0362
362
2 (SPWM)
120
41850
41850
414
2
107
350
414
0414
414
2 (SPWM)
120
400
477
0515
515
2 (SPWM)
120
42200
515
2
118
450
515
500
590
0675
675
2 (SPWM)
120
43000
675
2
120
600
—
800
—
0930
930
2 (SPWM)
120
—
—
—
—
1000
—
1200
1200
2 (SPWM)
120
—
—
—
—
480 V He avy Duty
NEC HP 460 V
NEC Amps
A1000 (C6-01 = 0)
F7 (C6-01 = 0)
A1000
Model
CIMR-AU4A
Output Amps
Heavy Duty
Fc kHz
Heavy
Duty
<1>
Overload %
Heavy Duty
F7
Model
CIMR-F7U
Output Amps
Heavy Duty
Fc kHz
Heavy Duty
Overload %
Heavy Duty