10 Appendix 2 Parameter Cross Reference
YASKAWA PL.A1000.02 F7 to A1000 - Product Transition Guide
33
PID Control
PID Output Level
Selection
b5-09
0
b5-09
0
b5-09
b5-09
0: Normal
0: Normal
1: Reverse
1: Reverse
PID Output Gain
Setting
b5-10
1.0
b5-10
1.00
Minimum setting units vary.
PID Output
Reverse Selection
b5-11
0
b5-11
0
b5-11
b5-11
0: Negative PID output
triggers zero limit
0: Negative PID output triggers zero limit
1: Rotation direction
reverses with negative PID
output.
1: Rotation direction reverses with negative PID output.
PID Feedback
Reference Missing
Detection
Selection
b5-12
0
b5-12
0
b5-12
b5-12
0: No Detection
0: No Detection
1: Alarm
1: Alarm and MFO (@PID enable only)
2: Fault
2: Fault and MFO (@PID enable only)
—
3: Multi-function output only (no display indication, @
PID enable/disable)
—
4: An alarm is triggered and the drive continues
running, @ PID enable/disable.
—
5: Fault is triggered and output is shut off, @ PID
enable/disable.
PID Feedback Loss
Detection Level
b5-13
0 %
b5-13
0 %
—
PID Feedback Loss
Detection Time
b5-14
1.0 s
b5-14
1.0 s
—
PID Control
PID Sleep
Function Start
Level
b5-15
0.0 Hz
b5-15
0.0 Hz
—
PID Sleep Delay
Time
b5-16
0.0 s
b5-16
0.0 s
—
PID Accel/Decel
Time
b5-17
0.0 s
b5-17
0.0 s
—
Dwell Function
Dwell Reference at
Start
b6-01
0.0 Hz
b6-01
0.0 Hz
—
Dwell Time at Start
b6-02
0.0 s
b6-02
0.0 s
—
Dwell Frequency
at Stop
b6-03
0.0 Hz
b6-03
0.0 Hz
—
Dwell Time at Stop
b6-04
0.0 s
b6-04
0.0 s
—
Droop Control
Droop Control
Level
b7-01
0.0 %
b7-01
0.0 %
—
Droop Control
Delay Time
b7-02
0.05 s
b7-02
0.05 s
—
Energy Saving
Control
Energy Saving
Control Selection
b8-01
0
b8-01
0*
b8-01
b8-01
0: Energy Saving disabled 0: Energy Saving disabled
1: Energy Saving enabled
1: Energy Saving enabled
*Determined by parameter A1-02.
Energy Saving
Gain
b8-02
1.0
b8-02
*
Determined by parameter A1-02.
Energy Saving
Control Filter Time
Constant
b8-03
Varies by
kVA
b8-03
*
Dependent on parameters A1-02, C6-01, and o2-04.
Energy Saving
Coefficient Value
b8-04
Varies by
kVA
b8-04
*
Dependent on parameters o2-04 and C6-01. Value changes automatically if E2-11 is
manually changed or changed by Auto-Tuning.
Power Detection
Filter Time
b8-05
20 ms
b8-05
20 ms
—
Search Operation
Voltage Limit
b8-06
0 %
b8-06
0 %
—
Zero Servo
Zero Servo Gain
b9-01
5
b9-01
5
—
Zero Servo
Completion Width
b9-02
10
b9-02
10
—
Parameter Name
F7
A1000
Setting
Parameter
Default
Parameter
Default
F7
A1000