10 appendix 2 parameter cross reference – Yaskawa F7 to A1000 User Manual
Page 40

10 Appendix 2 Parameter Cross Reference
40
YASKAWA PL.A1000.02 F7 to A1000 - Product Transition Guide
Analog Monitor
Card
Channel 1 Monitor
Selection
F4-01
2
F4-01
102
F4-01, F4-03, H4-01,
H4-04, o1-01
F4-01, F4-03, H4-01, H4-04, o1-01
01: Frequency reference
101: Frequency reference
02: Output frequency
102: Output frequency
03: Output current
103: Output current
05: Motor speed
105: Motor speed
06: Output voltage
reference
106: Output voltage reference
07: Main circuit DC
voltage
107: Main circuit DC voltage
08: Output power
108: Output power
09: Torque ref (Internal)
109: Torque ref (Internal)
15: Freq ref, A1 voltage
113: Freq ref, A1 voltage
16: Freq ref, A2 voltage
114: Freq ref, A2 voltage
17: Freq ref, A3 voltage
115: Freq ref, A3 voltage
18: Secondary current (Iq)
601: Secondary current (Iq)
19: Motor excitation
current (Id)
602: Motor excitation current (Id)
20: Output after soft start
116: Output after soft start
21: ASR input
603: ASR input
22: ASR output
604: ASR output
24: PID feedback amount
501: PID feedback amount
26: Output voltage ref
(Vq)
605: Output voltage ref (Vq)
27: Output voltage ref
(Vd)
606: Output voltage ref (Vd)
Analog Monitor
Card
Channel 1 Monitor
Selection
F4-01
2
F4-01
102
32: ACR output (q-axis)
607: ACR output (q-axis)
33: ACR output (d-axis)
608: ACR output (d-axis)
36: PID input amount
502: PID input amount
37: PID output amount
503: PID output amount
38: PID setpoint
504: PID setpoint
44: ASR output , no filter
625: ASR output , no filter
45: Feed Forward output
626: Feed Forward output
Terminal V1
Monitor Gain
F4-02
100.0 %
F4-02
100.0 %
—
Terminal V2
Monitor Selection
F4-03
3
*
F4-03
103
*
*See the comments column for F4-01.
Terminal V2
Monitor Gain
F4-04
50.0 %
F4-04
50.0 %
—
Terminal V1
Monitor Bias
F4-05
0.0 %
F4-05
0.0 %
—
Terminal V2
Monitor Bias
F4-06
0.0 %
F4-06
0.0 %
—
Terminal V1
Signal Level
F4-07
0
F4-07
0
F4-07
F4-07
0: 0 to 10 V
0: 0 to 10 V
1: -10 to +10 V
1: -10 to +10 V
Terminal V2
Signal Level
F4-08
0
F4-08
0
F4-08
F4-08
0: 0 to 10 V
0: 0 to 10 V
1: -10 to +10 V
1: -10 to +10 V
Parameter Name
F7
A1000
Setting
Parameter
Default
Parameter
Default
F7
A1000