• To connect the communication input, connect all eight conductors of the Ethernet cable to

the electronic assembly at terminal X9 (see Section 4.4, page 17) according to the
following table. Trim any overlapping conductors.

Signal

Terminal
X7 and X9

EIA/TIA 568B (eight-conductor)
Insulated conductor color

TX+

1
(white/orange)

white/orange

TX-

2
(orange/white or or-
ange)

orange/white or orange

RX+

3
(white/green)

white/green

not assigned

4
(blue/white or blue)

blue/white or blue

not assigned

5
(white/blue)

white/blue

RX-

6
(green/white or
green)

green/white or green

not assigned

7
(white/brown)

white/brown

not assigned

8
(brown/white or
brown)

brown/white or brown

5. Ensure that the Ethernet cables are securely connected.
6. Attach the Ethernet cables to the strain relief in the DC subdistribution using a cable tie.
7. Connect the Ethernet cable for the communication output in the inverter (see inverter manual)

or in the next DC subdistribution in the communication bus.

8. Secure the Ethernet cables to the external cable support rail.