2 mounting the sma string-monitor on the wall, Mounting the sma string-monitor on the wall – SMA SSM-U-1615 User Manual
Page 23
Observe minimum clearances:
Figure 9: Minimum clearances
Position
Explanation
A
200 mm
B
650 mm
C
800 mm
D
150 mm
E
650 mm
5.2
Mounting the SMA String-Monitor on the Wall
Risk of injury when lifting the DC sub-distribution, or if it is dropped
There is risk of injury if the DC sub-distribution is lifted incorrectly or dropped while being
transported or when attaching it to or removing it from the wall mounting bracket. Weight of the
DC sub-distribution without installed accessories: 35 kg.
• Two persons are required for mounting and disassembling the DC sub-distribution.
• Carefully lift and transport the DC sub-distribution.
Additionally required mounting material (not included in the scope of delivery):
• For mounting the DC subdistribution on a wall:
– 4 screws M6. Take the wall properties into account when selecting the screws.
– 4 washers
5 Mounting
SMA Solar Technology AG
Operating Manual
23
SSMUXX15-BE-en-10