beautypg.com

SMA SB 5000-US User Manual

Page 75

background image

SMA America, LLC

Displays and Messages

SB50US-80US-IA-en-37

SB50US-80US-IA-en-37

75

Default

USA/UL1741/

2005, OFF_Grid,

NON IEEE1547

USA/

UL1741/

2005

Electrically

qualified

person

Used for adjusting the country

specific parameter settings.
Note: After changing one of the

parameters marked with "*", the

parameter "default" changes to

"adjusted" automatically.

dFac-MAX*

Hz/s

0.005 ... 4

0.5 (for

country setting

USA/

UL1741/

2005)

Electrically

qualified

person

Maximum "number of frequency

changes" before the anti-islanding

protection switches on

E_total

kWh

0 ... 200000

0

Electrically

qualified

person

Total energy yield of the inverter.

Changing the value may be

necessary if a Sunny Boy is replaced

and you wish to compare the data

obtained previously.

Fac-delta–*

Hz

0.2 ... 3

0.69 (for

country setting

USA/

UL1741/

2005)

Electrically

qualified

person

Maximum permissible operating

frequency above and below 60 Hz.

Standard value is optimal for plants

< 30 kW.

Fac-delta+*

Hz

0 ... 4.5

0.49 (for

country setting

USA/

UL1741/

2005)

Electrically

qualified

person

Fac-MinTripTime*

s

0.16 ... 300

0.16

Electrically

qualified

person

Switch-off time having fallen below

power frequency. The standard

value is optimal for plants < 30 kW.

Fan-Test

1 / 0

0

Electrically

qualified

person

By setting this parameter to "1" you

can check the function of the fans.

This test turns the fans at maximum

speed.

h_Total

h

0 ... 200000

0

Electrically

qualified

person

Total operating hours of the inverter.

Changing the value may be

necessary if a Sunny Boy is replaced

and you wish to compare the data

obtained previously.

Memory Function

no function, Default

param., Reset

Op.Data, Reset

errors

no function

Electrically

qualified

person

Default param.: Sets all parameters

to the standard value.
Reset Op.Data: Sets all parameters

to the standard values that are

displayed on the user level.
Reset errors: Resets all permanent

errors that lead to device

disconnection.

Name

Unit

Range

Standard

Password

Level

Description

This manual is related to the following products: