beautypg.com

9 closing the dc disconnect, Closing the dc disconnect – SMA SB 5000-US User Manual

Page 57

background image

SMA America, LLC

Electrical Connection

SB50US-80US-IA-en-37

SB50US-80US-IA-en-37

57

6.9 Closing the DC Disconnect

.

1. Mount the cover onto the DC disconnect and insert

the rotary handle. Turn the rotary handle to position
"0".

2. Tighten the screw on the right side of the rotary

handle. Use a cross-head screwdriver (screw used:
UNC no. 5x

3

4

in. cross-head, flat-head).

3. Insert the screw and conical spring washer of the

DC disconnect into the underside. Tighten the screw with a torque of 44 in-lb. (5 Nm).

All string fuses must be securely mounted

The toothing of the conical spring washer must point toward the cover for the DC
disconnect to be grounded

1

3

2

4

GROUNDING

ELECTRODE

CONDUCTOR

COMBINED

1

2

3

4

UNGROUNDED

GROUNDED

L1 L2 N

1

3

2

4

COMBINED

1

2

3

4

UNGROUNDED

GROUNDED

This manual is related to the following products: