5.2 Requirements for the Mounting Location

Observe the following conditions during installation:

• The installation method and mounting location must be suitable for the weight and dimensions

of the Sunny Boy (see section 11 ”Technical Data” (page 91)).

• Note the dimensions of the DC disconnect (Page 34).
• Mount the inverter on a stable surface.
• The mounting location must be accessible at all times.

• Mount vertically or tilted backward at max. 45°.
• The connection area must point downward.
• Do not install the inverter tilting forward.
• Do not install the inverter horizontally.
• Install the inverter at eye level in order to be able to read out the operating state at any time.
• The ambient temperature must be below +113 °F (+45 °C).
• Do not expose the inverter to direct sunlight.
• In the living area, do not install inverters on a

plasterboard wall or similar wall.
The Sunny Boy may emit noises when in use which
can be regarded as a nuisance.

max. 45°