4 climatic conditions, 5 equipment, 6 torques – SMA STP 5000TL User Manual
Page 60: 4 climatic conditions 11.5 equipment 11.6 torques

Ground-fault monitoring for STP 5000TL-20 /
6000TL-20 / 7000TL-20 / 8000TL-20 /
9000TL-20
Insulation monitoring: R
iso
> 385 kΩ
Ground-fault monitoring for STP 10000TL-20 /
12000TL-20
Insulation monitoring: R
iso
> 200 kΩ
All-pole sensitive residual-current monitoring unit
Available
11.4 Climatic Conditions
Installation in accordance with IEC 60721-3-3, Class 4K4H
Extended temperature range
-25°C to +60°C
Extended humidity range
0% to 100%
Extended air pressure range
79.5 kPa to 106 kPa
Transport in accordance with IEC 60721-3-2, Class 2K3
Temperature range
-25°C to +70°C
11.5 Equipment
DC connection
SUNCLIX DC connector
AC connection
Spring-cage terminal
Display
LC graphic display
Bluetooth
As standard
Speedwire/Webconnect interface
As standard
Multifunction relay
As standard
SMA Power Control Module
Optional
RS485 interface
Optional
11.6 Torques
Enclosure lid screws
6.0 Nm ± 0.5 Nm
Protective cover screws
2.0 Nm
Additional grounding terminal
6.0 Nm
Cylindrical screw for attaching the enclosure to
the wall mounting bracket
6.0 Nm
SUNCLIX swivel nut
2.0 Nm
11 Technical Data
SMA Solar Technology AG
Operating Manual
STP5-10TL-20-BE-en-13
60