SMA STP 5000TL User Manual
Page 22

• Remove the inverter by lifting it vertically up and off the wall mounting bracket.
• Drill the hole or holes to attach the safety screw(s) and insert the screw anchor(s).
7. Hook the inverter into the wall mounting bracket.
8. Secure the inverter to the wall mounting bracket
on both sides using the M6x8 screws provided
and an Allen key (AF 5). Only tighten the screws
hand-tight.
9. Close the recessed grips with the ventilation grids. Ensure that the assignment is correct. The
correct assignment is marked on the inside of each ventilation grid: links/left for the left-hand
side and rechts/right for the right-hand side.
10. Once the holes for attaching the safety screw
have been pre-drilled, secure the inverter with at
least one safety screw through the pre-drilled
hole.
11. Ensure that the inverter is securely in place.
5 Mounting
SMA Solar Technology AG
Operating Manual
STP5-10TL-20-BE-en-13
22