3 sunny tripower 12000tl – SMA STP 5000TL User Manual
Page 56

STP 8000TL-20
STP 9000TL-20
STP 10000TL-20
Total harmonic distortion of the output
current with total harmonic distortion
of the AC voltage < 2%, and AC
power > 50% of the rated power
≤3%
≤3%
≤3%
Maximum output current under fault
conditions
20 A
22 A
25 A
Rated power frequency
50 Hz
50 Hz
50 Hz
AC power frequency*
50 Hz / 60 Hz
50 Hz / 60 Hz
50 Hz / 60 Hz
Operating range at AC power fre-
quency 50 Hz
45.5 Hz to
54.5 Hz
45.5 Hz to
54.5 Hz
45.5 Hz to
54.5 Hz
Operating range at AC power fre-
quency 60 Hz
55.5 Hz to
64.5 Hz
55.5 Hz to
64.5 Hz
55.5 Hz to
64.5 Hz
Displacement power factor cos φ, ad-
justable
0.8 underexcited
to 1 to
0.8 overexcited
0.8 underexcited
to 1 to
0.8 overexcited
0.8 underexcited
to 1 to
0.8 overexcited
Feed-in phases
3
3
3
Connection phases
3
3
3
Overvoltage category in accordance
with IEC 60664-1
III
III
III
* depending on the configured country data set
Efficiency
STP 8000TL-20
STP 9000TL-20
STP 10000TL-20
Maximum efficiency, η
max
98%
98%
98%
European efficiency, η
EU
97.6%
97.6%
97.6%
11.1.3 Sunny Tripower 12000TL
DC Input
STP 12000TL-20
Maximum DC power at cos φ = 1
12,275 W
Maximum input voltage
1,000 V
MPP voltage range
440 V to 800 V
Rated input voltage
580 V
Minimum input voltage
150 V
Initial input voltage
188 V
11 Technical Data