3 protective devices – SMA STP 5000TL User Manual
Page 59

Additional data volume when using the Sunny
Portal live interface
600 kB/hour
Topology
transformerless
Cooling concept
SMA OptiCool
Fan connection
Designed for safe disconnection in accordance
with DIN EN 62109
Degree of protection for electronics in accor-
dance with IEC 60529
IP65
Protection class in accordance with IEC 62103
I
Grid configurations
TN-C, TN-S, TN-C-S, TT (when V
N_PE
< 20 V)
Approvals and national standards, as per
06/2014*
AS 4777, CE, CEI 0-21, C10/11:2012,
DIN EN 62109-1, EN 50438, G59/3,
G83/2, IEC 61727/MEA IEC 61727/PEA,
IEC 62109-2, NEN EN 50438, NRS 097-2-1,
PPC, PPDS, RD 661/2007, RD 1699:2011,
SI 4777, UTE C15-712-1, VDE0126-1-1, VDE-
AR-N 4105, VFR 2013, VFR 2014
* AS 4777, SI 4777: For STP 12000TL-20 available as of October 2014
CE, EN 50438, G59/3, G83/2, IEC 62109-2, NEN EN 50438, NRS 097-2-1, PPC, PPDS,
RD 661/2007, RD 1699:2011, UTE C15-712-1, VDE AR-N 4105, VFR 2013, VFR 2014: For STP
12000TL-20 available as of September 2014
CEI 0-21: only permitted with external decoupling protection. For STP 12000TL-20 available as of
September 2014
C10/11:2012: only possible if the three-phase line-to-line voltage is 400 V.
IEC 61727/MEA and IEC 61727/PEA:only applicable for STP 9000TL-20.
EN 50438: does not apply to all national appendices of EN 50438.
IEC 62109-2: This standard requires that either the multifunction relay in the inverter is used as fault
indicator or that the inverter is connected to Sunny Portal and that the fault alert is activated in
Sunny Portal.
NRS 97-2-1: This standard requires a separate label be attached to the AC distribution board to
indicate the AC-side disconnection of the inverter in case of a grid failure (for further details, see
NRS 97-2-1, Sect. 4.2.7.1 and 4.2.7.2).
11.3 Protective Devices
DC reverse polarity protection
Short-circuit diode
Input-side disconnection point
Electronic Solar Switch, SUNCLIX DC connector
DC overvoltage protection
Thermally monitored varistors
AC short-circuit current capability
Current control
Grid monitoring
SMA Grid Guard 4
Maximum permissible fuse protection
32 A
11 Technical Data
SMA Solar Technology AG
Operating Manual
59
STP5-10TL-20-BE-en-13