8 configuration, 1 procedure, 2 changing the display language – SMA STP 5000TL User Manual
Page 42: Configuration, Procedure, Changing the display language

8 Configuration
8.1 Procedure
Once you have commissioned the inverter, you may have to adjust various settings via the rotary
switches in the inverter or via a communication product. This section describes the procedure for
configuration and gives an overview of the steps you must perform in the prescribed order.
Procedure
See
1.
If the display language is not set correctly, adjust the set-
tings.
2.
If you want to integrate the inverter into a Speedwire net-
work, connect the inverter to the network.
3.
To manage the PV system data or to set the inverter pa-
rameters, capture the inverter in a communication product.
Manual of the communica-
tion product at
Solar.com
4.
Change the PV system time and PV system password.
Manual of the communica-
tion product at
Solar.com
5.
If a residual-current device with a tripping threshold of
30 mA was required and used, you must set the tripping
threshold of the residual-current device.
6.
If using the multifunction relay, ensure that the operating
mode is set correctly and adjust any further settings for the
operating mode as necessary.
7.
Activate and set SMA OptiTrac Global Peak for partially
shaded PV modules.
8.2 Changing the Display Language
If the language for the country data set is not the language you want to use, you can change the
display language as follows:
1.
Danger to life due to high voltages
• Disconnect the inverter from all voltage sources and open the enclosure lid (see
8 Configuration
SMA Solar Technology AG
Operating Manual
STP5-10TL-20-BE-en-13