beautypg.com

2 led signals, 3 activating and operating the display, Led signals – SMA STP 5000TL User Manual

Page 49: Activating and operating the display

background image

Position

Symbol

Explanation

Q

-

Diagram with the power curve of the last 16 feed-in hours or
energy yields of the last 16 days

• In order to switch between the displays, tap once on the

enclosure lid.

R

You can operate the display by tapping on the enclosure lid
(see Section 9.3, page 49).

The displayed error must be rectified on-site by a qualified per-
son (for troubleshooting, see service manual at www.SMA-So-
lar.com).

The displayed error cannot be rectified on-site.

• Contact the SMA Service Line.

9.2 LED Signals

The LEDs indicate the operating state of the inverter.

LED

Status

Explanation

Green LED

glowing

Operation

flashing

The requirements for the connection to the utility
grid have not been met.

Red LED

glowing

An error has occurred that must be rectified by a
qualified person (for troubleshooting, see ser-
vice manual at www.SMA-Solar.com).

Blue LED

glowing

Active communication via Bluetooth

9.3 Activating and Operating the Display

You can activate and operate the display by tapping on the enclosure lid.

1. Activate the display. Tap on the enclosure lid once.

☑ The backlight is switched on.

2. To move to the next line, tap on the enclosure lid once.
3. In order to switch between the power curve of the last 16 feed-in hours and the energy yields

of the last 16 days in the diagram, tap on the enclosure lid once.

9 Operation

SMA Solar Technology AG

Operating Manual

49

STP5-10TL-20-BE-en-13

This manual is related to the following products: