Tool table: Tool data for automatic speed/feed rate calculation.

Tool table: Tool data for 3-D touch trigger probe (only when bit 1
is set in MP7411 = 1, also see the Touch Probe Cycles Manual)

RTOL

Permissible deviation from tool radius R for wear detection. If the
entered value is exceeded, the TNC locks the tool (statusL). Input
range: 0 to 0.9999 mm

Wear tolerance: radius?

DIRECT.

Cutting direction of the tool for measuring the tool during rotation

Cutting direction (M3 = –)?

TT:R-OFFS

For tool length measurement: Tool offset between stylus center
and tool center. Preset value: Tool radius R (NO ENT means R).

Tool offset: radius?

TT:L-OFFS

Tool radius measurement: Tool offset in addition to MP6530
between upper surface of stylus and lower surface of tool.
Default: 0

Tool offset: length?

LBREAK

Permissible deviation from tool length L for breakage detection. If
the entered value is exceeded, the TNC locks the tool (statusL).
Input range: 0 to 0.9999 mm

Breakage tolerance: length?

RBREAK

Permissible deviation from tool radius R for breakage detection. If
the entered value is exceeded, the TNC locks the tool (status L).
Input range: 0 to 0.9999 mm

Breakage tolerance: radius?

Abbr.

Input

Dialog

Abbr.

Input

Dialog

TYPE

Tool type: Press the SELECT TYPE (3rd soft-key row); the TNC
superimposes a window where you can select the type of tool
you want. Functions are currently only assigned to the DRILL and
MILL tool types.

Tool type?

TMAT

Tool material: Press the SELECT MATERIAL soft key (3rd soft-key
row): The TNC superimposes a window where you can select the
type of material you want.

Tool material?

CDT

Cutting data table: Press the SELECT CDT soft key (3rd soft-key
row): The TNC superimposes a window where you can select a
cutting data table.

Name of cutting data table?

Abbr.

Input

Dialog

CAL-OF1

During calibration, the TNC stores in this column the center
misalignment in the reference axis of the 3-D probe, if a tool
number is indicated in the calibration menu.

Center misalignmt. in ref. axis?

CAL-OF2

During calibration, the TNC stores in this column the center
misalignment in the minor axis of the 3-D probe, if a tool number
is indicated in the calibration menu.

Center misalignment minor axis?

CAL-ANG

During calibration, the TNC stores in this column the spindle angle
at which the 3-D probe was calibrated, if a tool number is
indicated in the calibration menu.