2 t ool d a ta – HEIDENHAIN iTNC 530 (340 49x-02) User Manual
Page 168

168
5 Programming: Tools
5.2 T
ool D
a
ta
Tool table: Tool data for automatic speed/feed rate calculation.
Tool table: Tool data for 3-D touch trigger probe (only when bit 1
is set in MP7411 = 1, also see the Touch Probe Cycles Manual)
RTOL
Permissible deviation from tool radius R for wear detection. If the
entered value is exceeded, the TNC locks the tool (statusL). Input
range: 0 to 0.9999 mm
Wear tolerance: radius?
DIRECT.
Cutting direction of the tool for measuring the tool during rotation
Cutting direction (M3 = –)?
TT:R-OFFS
For tool length measurement: Tool offset between stylus center
and tool center. Preset value: Tool radius R (NO ENT means R).
Tool offset: radius?
TT:L-OFFS
Tool radius measurement: Tool offset in addition to MP6530
between upper surface of stylus and lower surface of tool.
Default: 0
Tool offset: length?
LBREAK
Permissible deviation from tool length L for breakage detection. If
the entered value is exceeded, the TNC locks the tool (statusL).
Input range: 0 to 0.9999 mm
Breakage tolerance: length?
RBREAK
Permissible deviation from tool radius R for breakage detection. If
the entered value is exceeded, the TNC locks the tool (status L).
Input range: 0 to 0.9999 mm
Breakage tolerance: radius?
Abbr.
Input
Dialog
Abbr.
Input
Dialog
TYPE
Tool type: Press the SELECT TYPE (3rd soft-key row); the TNC
superimposes a window where you can select the type of tool
you want. Functions are currently only assigned to the DRILL and
MILL tool types.
Tool type?
TMAT
Tool material: Press the SELECT MATERIAL soft key (3rd soft-key
row): The TNC superimposes a window where you can select the
type of material you want.
Tool material?
CDT
Cutting data table: Press the SELECT CDT soft key (3rd soft-key
row): The TNC superimposes a window where you can select a
cutting data table.
Name of cutting data table?
Abbr.
Input
Dialog
CAL-OF1
During calibration, the TNC stores in this column the center
misalignment in the reference axis of the 3-D probe, if a tool
number is indicated in the calibration menu.
Center misalignmt. in ref. axis?
CAL-OF2
During calibration, the TNC stores in this column the center
misalignment in the minor axis of the 3-D probe, if a tool number
is indicated in the calibration menu.
Center misalignment minor axis?
CAL-ANG
During calibration, the TNC stores in this column the spindle angle
at which the 3-D probe was calibrated, if a tool number is
indicated in the calibration menu.
Spindle angle for calibration?