Test Run and Program Run

14.5 Pr

ogr

am Run

U

Go to the first block of the current program to start a block scan:
Enter GOTO "0"

U

To select block scan, press the BLOCK SCAN soft key,

or

U

Start-up at N:

Enter the block number N at which the

block scan should end

U

Program:

Enter the name of the program containing

block N

U

Repetitions:

If block N is located in a program section

repeat or in a subprogram that is to be run repeatedly,
enter the number of repetitions to be calculated in the
block scan

U

To start the block scan, press the machine START

button

U

Contour approach (see following section)

Entering a program with the GOTO key

If you use the GOTO block number key for going into a
program, neither the TNC nor the PLC will execute any
functions that ensure a safe start.

If you use the GOTO block number key for going into a
subprogram,

„

the TNC will skip the end of the subprogram (G98 L0)

„

the TNC will reset function M126 (Shorter-path traverse
of rotary axes)

In such cases you must always use the mid-program