Circle center as datum, 8 set the dat um with a 3-d t o uc h pr obe – HEIDENHAIN TNC 320 (340 55x-05) ISO programming User Manual
Page 352

352
Manual Operation and Setup
12.8 Set the dat
um with a 3-D t
o
uc
h pr
obe
Circle center as datum
With this function, you can set the datum at the center of bore holes,
circular pockets, cylinders, studs, circular islands, etc.
Inside circle:
The TNC automatically probes the inside wall in all four coordinate axis
directions.
For incomplete circles (circular arcs) you can choose the appropriate
probing direction.
U
Position the touch probe approximately in the center of the circle.
U
Select the probe function by pressing the PROBING
CC soft key
U
To probe the workpiece, press the machine START
button four times. The touch probe touches four
points on the inside of the circle.
U
Datum
: In the menu window, enter both coordinates of
the circle center, confirm with the SET DATUM soft
key, or write the values to a table (see "Writing the
measured values from touch probe cycles in datum
tables", page 343, or see "Writing the measured
values from touch probe cycles in the preset table",
page 343)
U
To terminate the probe function, press the END soft
key
Outside circle:
U
Position the touch probe at a position near the first touch point
outside of the circle.
U
Select the probe direction by soft key.
U
To probe the workpiece, press the machine START button.
U
Repeat the probing process for the remaining three points. See
figure at lower right.
U
Datum
: Enter the coordinates of the datum and confirm your entry
with the SET DATUM soft key, or write the values to a table (see
"Writing the measured values from touch probe cycles in datum
tables", page 343, or see "Writing the measured values from touch
probe cycles in the preset table", page 343)
U
To terminate the probe function, press the END soft key
After the probing procedure is completed, the TNC displays the
coordinates of the circle center and the circle radius PR
X
Y
X+
X
Y+
Y
X
Y
X+
X
Y+
Y
HEIDENHAIN only gives warranty for the function of the
probing cycles if HEIDENHAIN touch probes are used.
If you use probing functions in a tilted working plane, you
must set 3-D ROT to Active for the Manual Operation and
Automatic operating modes.