beautypg.com

2 pr eset ting aut o matically – HEIDENHAIN TNC 320 (340 55x-03) Touch Probe Cycles User Manual

Page 83

background image

HEIDENHAIN TNC 320

83

3.2 Pr

eset

ting aut

o

matically

8

Measuring height in the touch probe axis

Q261

(absolute): Coordinate of the ball tip center (= touch
point) in the touch probe axis in which the
measurement is to be made.

8

Setup clearance

Q320 (incremental): Additional

distance between measuring point and ball tip. Q320
is added to column SET_UP.

8

Clearance height

Q260 (absolute): Coordinate in the

touch probe axis at which no collision between tool
and workpiece (fixtures) can occur.

8

Traversing to clearance height

Q301: Definition of

how the touch probe is to move between the
measuring points:
0: Move at measuring height between measuring
points
1: Move at clearance height between measuring
points

8

Datum number in table

Q305: Enter the datum

number in the table in which the TNC is to save the
coordinates of the pocket center. If you enter
Q305=0, the TNC automatically sets the display so
that the new datum is on the stud center.

This manual is related to the following products: