3.2 Pr

eset

ting aut

o

matically

8

Center in 1st axis

Q321 (absolute value): Center of

the slot in the reference axis of the working plane.

8

Center in 2nd axis

Q322 (absolute value): Center of

the slot in the minor axis of the working plane.

8

Width of slot

Q311 (incremental): Width of the slot,

regardless of its position in the working plane.

8

Measuring axis (1=1st axis / 2=2nd axis)

Q272:

Axis in which the measurement is to be made:
1: Reference axis = measuring axis
2: Minor axis = measuring axis

8

Measuring height in the touch probe axis

Q261

(absolute): Coordinate of the ball tip center (= touch
point) in the touch probe axis in which the
measurement is to be made.

8

Setup clearance

Q320 (incremental): Additional

distance between measuring point and ball tip. Q320
is added to column SET_UP.

8

Clearance height

Q260 (absolute): Coordinate in the

touch probe axis at which no collision between tool
and workpiece (fixtures) can occur.

8

Traversing to clearance height

Q301: Definition of

how the touch probe is to move between the
measuring points:
0: Move at measuring height between measuring
points
1: Move at clearance height between measuring
points

8

Number in table

Q305: Enter the number in the

datum/preset table in which the TNC is to save the
coordinates of the slot center. If you enter Q305=0,
the TNC automatically sets the display so that the
new datum is on the slot center.

8

New datum

Q405 (absolute): Coordinate in the

measuring axis at which the TNC should set the
calculated slot center. Basic setting = 0

X

Y

Q322

Q321

Q31

1

MP6140

+

Q320

X

Z

Q261

Q260